≥88% at full load(see orderable parts table for details)
Ac Current
1.7@115VAC and 0.9A @230Vac
Inrush Current(Typ#)
≤65A@230VAC cold start with full load
Leakage Current
≤0.75mA@277VAC
THD(Total Harmonic Dist#)
<25% at full load
Output Information
Rated Power
150W(Max.)
DC Voltage Range
12-48VDC(see output setting table)
Rated Current Range
3.1-12A(see output setting table)
Load Regulation
±5%
Turn On Time
<1s at full load
Dimming
Dimming interface
0/1-10V
Modes
Standard DC 0/1-10V control interface, Sink or Source <1mA 10V PWM dimming control, Wide dimming range from 0% up to 100%, Dimming Over entire input voltage voltage
Protections
Short Circuit
Hiccup mode protection. Recovers automatic after fault condition is removed.
Over Voltage
<30% above the maxmum output voltage listed for the specific part number.Latch mode-unit needs to be power cycled to recover
Over Current
<10% above the maximum output current listed for the specific part number. The unit limits the current. Unit autorecovers after fault is removed
Over Temperature
Unit turns off when Tc>90℃.Shuts down-unit needs to be power cycled to recover
Environment & Approbation
Working Temperature
_30℃ ---+70℃ at Full load
Working Humidity
20% --- 90% RH non-condensing
Storage Temperature, Humidity
_40°C --- + 80°C, 10% --- 90% RH non-condensing
Vibration
10 - 500Hz, 2G 10min/1 cycle period for 60 minutes along each axis (X, Y, Z)